Skip to main content

Table 4 Specificity of four immunodiagnostic kits for clonorchiasis in China

From: Performance evaluation of existing immunoassays for Clonorchis sinensis infection in China

Kit

Negative sera (Control 1) (n = 120)

Healthy sera (Control 2) (n = 50)

Heterologous sera (Control 3) (n = 67)

Total (n = 237)

No. of false positives

Specificity (%) (95% CI)

No. of false positives

Specificity (%) (95% CI)

No. of false positives

Specificity (%) (95% CI)

No. of false positives

Specificity (%) (95% CI)

T1

16

86.67 (80.58–92.75)

2

96 (90.57–100)

20

70.15 (59.68–81.5)

38

83.97 (79.29–88.64)

T2

12

90 (84.63–95.37)

1

98 (94.12–100)

17

74.63 (64.63–85.37)

30

87.34 (83.11–91.58)

T3

39

67.5 (59.10–75.88)

3

94 (87.42–100)

21

68.66 (58.05–80.18)

63

73.42 (67.79–79.04)

T4

23

80.83 (73.79–87.88)

2

96 (90.57–100)

10

85.07 (76.81–93.77)

35